Industrial Automation & Switching Equipments

 
  • SIRCO
    3, 4, 6 or 8 Poles
    From 125 to 4000 A
    Direct operation or external front operation

  • SIDERMAT
    3 or 4 poles
    From 250 to 1800 A
    Direct operation or external operation

  • MOTORIZED SIRCO
    3 or 4 poles
    From 125 to 3200 A
    9 ratings
    230 VAC

  • SIDER
    3 or 4 poles
    (N-pole SIDER ND)
    From 125 to 1600 A
    Direct Operation
    External Front Operation
    Left/Right Side Operation

  • LOAD BREAK SWITCH SIRCO PV
    Up to 1000 V d.c.
    3,4,6 and 8 Poles
    From 100 to 1250A
    Load duty categories DC-21 or DC-22 External or direct front operation

  • SIRCO HIGH WITHSTAND
    3 or 4 poles{2000 to 3200 A}
    Fully visible breaking
    High thermal ans dynamic withstand : 80kA 1s, 110 kA 0.1s Severe utilisation categories (AC-22 and AC-23)

  • SIRCO M & MV
    3, 4 , 6 and 8 poles
    From 16 to 160 A
    Can be operated directly using rotary handle or lever control (toggle), external front control, left side control or right side control, Changeover switches I-0-II and I-I+II-II

 
 
  • COUNTIS E00/E02
    For single phases LV network
    Direct input up to 32 A
    1 fixed 100 Wh impulse output
    1 module
    IEC 62053-21 class 1

  • COUNTIS E10/E11/E12
    For single phase LV network
    Direct connection up to 63 A
    +kWh metering; MID version
    Active power measurement
    1 impulse output
    Dual tariff version

  • COUNTIS E20/E21
    For three phases LV network
    Direct connection up to 63 A
    +kWh metering
    Activ power measurement
    1 impulse output
    Dual tariif version

  • COUNTIS E30/E31/E32/E33/E34
    For three phases LV network
    Direct connection up to 100 A
    +kWh and + kvarh metering
    Active power measurement
    1 Impulse Output or
    JBUS/MODBUS RS485 serial port; MID version
    Dual tariff version

  • COUNTIS E40/E41/E42/E43/E44
    For three phases LV network
    Connection up to 6000A via current transformer
    +kWh and + kvarh metering
    Active and reactive power measurement
    1 impulse output or JBUS/MODBUS RS485 serial port
    MID Version; Dual tariff version

  • COUNTIS E50/E53
    For three phases LV network
    Connection up to 6000A via current transformer
    +kWh and + kvarh metering
    Active and reactive power measurement
    Voltage, current and power factor measurement
    1 impulse output or JBUS/MODBUS RS485 serial port; Multi tariff

  • COUNTIS E63
    Direct connection up to 100 A
    • +kWh metering
    • Active power measurement
    • JBUS/MODBUS RS485 serial port
    • 4 tariffs via RS485 communication
    • Instantaneous currents: I1, I2, I3 via RS485
    • Instantaneous voltages: U1, U2, U3 via RS485
    • Instantaneous power: 3P, 3S via RS485
    • Instantaneous power factors: 3PF via RS485
    • Load curves for each of the 3 phases via RS485 : reproduction of average positive active power energy consumption demand for a programmable period.

  • COUNTIS EC12/EC13
    7 partial, overall, daily, weekly or monthly totalisers to account for the kWh or other type of quantities (liters, cubic meters, Euros…)
    • 2 analogue inputs 0/4 ... 20mA
    • Load curves values stored for 170 days (10 min)
    • Status of the inputs
    • Compatible with ENERGY REPORTING software
    • JBUS/MODBUS® RS485 serial port
    • 1 configurable logical output

 
 
  • Industrial Fuses Links
    DIN
    • Sizes: 10x38, 14x51, 22x58, T000, T00, T0, T1, T2, T3, T4
    • From 0.16 A to 1250 A
    • With or without striker
    • 500 or 690 V AC
    BS
    • Sizes : A1 to A4, B1 to B4, C1 to C3, D1, F1, F2
    • From 2 to 1250 A
    • 415 or 550 V AC

  • High Speed Fuses
    • Sizes: 14x51; 22x58; T0000, T000, T0, T1, T1*, T2, T3
    • From 5 to 2000 A
    • 690 V AC or 1250 V AC
    • Multiple connection types (brackets, tapped holes, knives…)

  • PV Fuses
    • Sizes: 10x38 without striker
    • From 2 to 20 A
    • High breaking capacity of 30 kA at 900 V d.c.

 
 
  • FUSERBLOC AND HIGH SPEED FUSES(UR)
    • 2, 3 or 4 poles
    • From 10 to 2000 A
    • Direct operation or external front or side operation

  • SIDERMAT COMBINATION
    • 3 or 4 poles
    • From 630 to 1800 A
    • Direct operation or external front operation

  • FUSERBLOC
    • NFC, DIN, BS and UR multi-standard fuses
    • Direct operation or external front or left/right side operation
    • Operation with integrated TEST function

  • FUSOMAT
    • 3 or 4 poles
    • From 250 to 1250 A
    • IEC, NF, DIN, BS and UR multi-standard fuses
    • Direct operation or external front or right side operation
    • Shunt-trip opening